Logotype Gsp Project
WATER AND WASTEWATER TECHNOLOGIES

You are here

Mechanical filters

Mechanical filters MF series

High efficiency mechanical filters are meant to separate the solids with dimensions over 1,5 mm, sediment from primary sedimentation and active sludge after secondary sedimentation from wastewater. The efficiency of suspended substance treatment is about 20-23%.

Use of mechanical filters guarantees stable operation of tertiary treatment unit and allow to avoid the sand separators and pre-treatment tanks. They are used at the WWTP with performance 1-1000 m3 per day.

Efficiency raw sludge treatment

Angle mesh (angle degree )

Suspended materials

concentration (g/l)

input

Suspended materials

concentration (g/l)

filtrate

 Humidity cake(%)

Efficiency of delaying

of suspended substances (%)

25 12,6 9,5-9,8 91,6-92,8 25-22
35 12,6 9,5-9,8 90,2-91,3 24-22
45 12,6 9,5-9,8 88,7-90,1 23-22

Efficiency activated sludge treatment

Angle mesh (angle degree )

Suspended materials

concentration (g/l)

input

Suspended materials

concentration (g/l)

filtrate

Efficiency of delaying

of suspended substances (%)

25 4,7-4,9 4,45-4,75 3,2-3,1
35 4,9-5,4 4,75-5,22 3,3-3
45 4,6-5,1 4,46-4,95 2,9-2,7

Performance specifications

Specifications MFO MFO/1 MF1 MF2 MF3
Technical output rate within (m3/h) 3-8 10-15 20-50 60-100 120-200
Space filter mesh, not more than (mm) 2 2 2 2 2
Average life till discarding at least (years) 20 20 20 20 20
Dimensions          
A 700 700 1130 1180 1152
B 430 720 690 1390 2500
C 1500 1500 2100 2100 2100